International Mechanical Code 2021 / International Code Council.
Material type:
- text
- unmediated
- volume
- 160983965X
- 9781609839659
- 1609839641
- 9781609839642
- 2021 International Mechanical Code
- IMC : International Mechanical Code 2021
- 2021 IMC
- 2021 IMC : International Mechanical Code
- Heating -- Law and legislation -- United States
- Ventilation -- Law and legislation -- United States
- Refrigeration and refrigerating machinery -- Safety regulations -- United States
- Building laws -- United States
- Building laws
- Mechanical engineering -- Handbooks, manuals, etc
- Mechanical engineering -- Law and legislation
- G�enie m�ecanique -- Guides, manuels, etc
- Building laws
- Heating -- Law and legislation
- Mechanical engineering
- Mechanical engineering -- Law and legislation
- Refrigeration and refrigerating machinery -- Safety regulations
- Ventilation -- Law and legislation
- United States
- 343.7307/869 23
- TH219 .I5 2020 v. 4
Item type | Current library | Call number | Copy number | Status | Date due | Barcode | Item holds | Course reserves | |
---|---|---|---|---|---|---|---|---|---|
![]() |
Richfield Campus Library Items Available at the Front Desk | INDM TH219 .I5 2020 v. 4 | 1 | Available | 34230000163926 |
Edition statement from page iii.
"A member of the International Code Family."
Includes index.
"Establishes minimum regulations for mechanical systems using prescriptive and performance-related provisions. The IMC was developed with broad-based principles that make possible the use of new materials, methods and design.Important changes in the edition include:Clothes dryer exhaust terminals required to be at least 3 feet from any opening into a building.Polyurethane spray-applied foam on the exterior of ducts in attics and crawl spaces required to meet specific smoke and flame index limits.Fire and smoke dampers must be provided with approved access for inspection and maintenance.Refrigerant tables updated to include new refrigerants.Addition of condensate termination identification markings and discharge restrictions.Approved factory-built combination intake/exhaust terminations permitted, relaxing separation requirement.30% reduction in minimum mechanical ventilation for whole-house balanced ventilation systems.Continuous operation requirement for manicure and pedicure station exhaust systems.Grease duct horizontal cleanout required within 3 feet of a horizontal discharge fan." -- Publisher website.
There are no comments on this title.